The time transformations
Transformation LOCTRANS12 requires one configuring line on which a time
transformation, automatically performed below the call to PSMILe prism_put_proto, should be indicated:
- INSTANT: no time transformation, the instantaneous field is
transferred;
- ACCUMUL: the field accumulated over the previous coupling
period is exchanged (the accumulation is simply done over the arrays
field_array provided as third argument to the prism_put_proto calls, not weighted by the time interval
between these calls);
- AVERAGE: the field averaged over the previous coupling
period is transferred (the average is simply done over the arrays
field_array provided as third argument to the prism_put_proto calls, not weighted by the time interval
between these calls);
- T_MIN: the minimum value of the field
for each source grid point over the previous coupling period is
transferred;
- T_MAX: the maximum value of the field for each source grid
point over the previous coupling period is transferred;
- ONCE: only one prism_put_proto or prism_get_proto will be performed; this is equivalent to giving the
length of the run as coupling or I/O period.
Footnotes
- ...LOCTRANS12
- Note that LOCTRANS cannot be
chosen with the deprecated SIPC, PIPE, or GMEM communication
techniques.